1. Control Baseline (Standard SWAP)
Readout measurements against standard physical SWAP transport.
{"1": 362, "0": 1638}
2. Depth Scaling (Topological Echo)
Readout retention across N round trips.
| Round Trips | '0' Count | '1' Count |
|---|---|---|
| 1 | 1573 | 427 |
| 3 | 1502 | 498 |
| 5 | 1402 | 598 |
3. True Topology (Local Perturbation)
Stability of the '0' state against injected Rz(θ) errors.
| θ Value (rad) | '0' Retention (%) |
|---|---|
| 0.00 | 82.5% |
| 0.79 | 81.2% |
| 1.57 | 81.6% |
| 2.36 | 81.9% |
| 3.14 | 80.9% |